生态与农村环境学报 ›› 2021, Vol. 37 ›› Issue (11): 1378-1385.doi: 10.19741/j.issn.1673-4831.2021.0377

• 区域环境与发展 • 上一篇    下一篇

河北石家庄城市人工河流缓解热岛效应研究

刘亚楠1, 陈艳梅1, 邹长新2, 李涵聪1, 李鑫1   

  1. 1. 河北师范大学地理科学学院/河北省环境变化遥感识别技术创新中心/河北省环境演变与生态建设重点实验室, 河北 石家庄 050024;
    2. 生态环境部南京环境科学研究所, 江苏南京 210042
  • 收稿日期:2021-06-11 发布日期:2021-11-18
  • 通讯作者: 陈艳梅,E-mail:330896729@qq.com E-mail:330896729@qq.com
  • 作者简介:刘亚楠(1997-),女,河南周口人,主要研究方向为区域生态学。E-mail:1341676572@qq.com
  • 基金资助:
    国家社会科学基金(20BJY047)

Alleviating Heat Island Effect of Urban Artificial Rivers in Shijiazhuang, Hebei Province

LIU Ya-nan1, CHEN Yan-mei1, ZOU Chang-xin2, LI Han-cong1, LI Xin1   

  1. 1. School of Geographical Sciences, Hebei Normal University/Hebei Technology Innovation Center for Remote Sensing Identification of Environmental Change/Laboratory of Environmental Evolution and Ecological Construction of Hebei Province, Shijiazhuang 050024, China;
    2. Nanjing Institute of Environmental Sciences, Ministry of Ecology and Environment, Nanjing 210042, China
  • Received:2021-06-11 Published:2021-11-18

摘要: 基于石家庄市2016年8月31日遥感影像数据,采用缓冲区分析方法开展石家庄市三环内人工河流-民心河降温效应研究。结果表明,(1)石家庄市3环内城市热场变异指数(UTFVI)范围为-0.23~0.37,市区城镇建设用地分布与UTFVI高值区分布相对应,城市水体及绿地分布与UTFVI低值区分布相一致,其中,民心河全线平均地表温度为35.82℃,平均UTFVI值<0.02,在城市高温区中形成条带状"冷区"。(2)民心河全线平均降温距离为165 m,在两岸缓冲区内,平均地表温度随缓冲距离的增加先迅速上升,后基本保持不变。(3)民心河各线平均UTFVI值均≤ 0.05,其中,民心河东线降温效果最好,降温距离可达到210 m,降温幅度为1.59℃;第二民心河降温效果最差,降温距离为60 m,降温幅度约为0.19℃。民心河西线、南线、北线和中线降温距离分别为150、120、180和270 m,降温幅度分别为0.65、0.40、1.60和1.39℃。(4)在民心河最小降温距离(60 m)内,且绿地面积占比>50%及城镇建设用地面积占比<48%时,水体平均UTFVI值≤ 0,存在冷岛效应,此时民心河与绿地的综合降温作用最大。研究结果将为城市人工河流建设及沿岸景观结构合理布局提供参考。

关键词: 石家庄民心河, 地表温度, 土地类型, 降温效应, 缓冲区

Abstract: As the urban heat island (UHI) effect has been intensified, cooling effect of urban artificial rivers has gradually gained more attention. Based on the remote sensing image of Shijiazhuang City on August 31, 2016, the cooling effect of the artificial Minxin River in the third ring road of Shijiazhuang City was evaluated by using buffer analysis method. The results show that:(1) The range of urban thermal field variation index (UTFVI) within the third ring road of Shijiazhuang City was -0.23-0.37. The high values of UTFVI represent the urban construction land, while the low values of UTFVI represent the water bodies and green spaces. The average surface temperature of Minxin River was 35.82℃, and its average UTFVI was lower than 0.02, leading to a strip-shaped " cold zone" in the urban region with high-temperature area. (2) The average cooling distance across the Minxin River was 165 m. Within the buffer zone on both sides of the river, the average surface temperature raised rapidly with the increasing buffer distance and then basically remained unchanged. (3) The average UTFVI values in the whole region of Minxin River were lower than 0.05. The cooling effect of east line of Minxin River was the best, the cooling distance reached to 210 m, and the cooling amplitude was 1.59℃. The cooling effect of the second Minxin River is the worst, and the cooling distance was only 60 m, and the cooling amplitude was about 0.19℃. The cooling distances of the west, south, north and middle lines of Minxin River were 150, 120, 180 and 270 m, respectively, and the corrsponding cooling amplitudes were 0.65, 0.40, 1.60 and 1.39℃, respectively. (4) Within 60 m of the minimum cooling distance of the Minxin River, a cold island effect occured when the proportion of green space was higher than 50%, the proportion of urban construction land was lower than 48%, and the average UTFVI of the urban water body was lower than zero. At that time, the comprehensive cooling effect of green space and the Minxin River was the largest. The research will provide guidance for construction of urban artificial rivers and the rational layout of shoreside landscape structures.

Key words: Minxin River of Shijiazhuang City, land surface temperature, land cover type, cooling effect, buffer zone

中图分类号: